Workhorse Switches and Connections

The Operator Control Console top includes the following switches:

SWITCHLOCATIONFUNCTION
Main Power SwitchTop LeftTurns the Operator Control Console on and off.
ROV Power SwitchCenter LeftTurns the ROV power on and off. Twist in the direction of the arrows to turn on the ROV power and press the switch to turn it off.
LIM ModuleCentral RightTest and Reset buttons can be found on the LIM.

The Operator Control Console top includes the following connections:

CONNECTIONLOCATIONFUNCTION
Power (100-240 Volts AC, 50, 60 Hz)IEC maleUsed to connect the Operator Control Console to a power source.

The Operator Control Console side includes the following switches:

SWITCHLOCATIONFUNCTION
12 VDC Circuit BreakerBottom LeftUSed to protect the 12 V DC power for topside accessories.

The Operator Control Console side includes the following connections:

CONNECTIONTYPEFUNCTION
Tether Whip (Specifications)8 pin round femaleUsed to connect the Operator Control Console to the tether for ROV power, communications, video and accessory support.
Monitor Power and Touch Screen ConnectionProvides 12 Volts DC. Used to provide power and touch screen function to the monitor.
Monitor SignalHDMI, female (2)Used to provide the video signal to the monitor.
USB Ports (7)Type A femaleCan be used to connect USB devices to the computer via the Operator Control Console.
@ are dedicated to the keyboard and hand controller. 5 additional are available for other devices.
EthernetRJ-45 femaleCan be used to connect the Operator Control Console to the computer for Ethernet based ROV accessories.
12 VDCDC Type M female (2)Can be used to to provide 12 V DC power to topside accessories.